As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ACFT IN C-CHECK WHEN THE INBD SIDE OF THE LT OMEGA BEAM WAS FOUND CORRODED AT FR 54 THRU FR 58. MX BLENDED THE SURFACE CORROSION IAW SRM 51-10-03 AND ALODINED, PRIMED AND PAINTED IAW CPM 51-21-07. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.