What was found
TYS - CORROSION WAS FOUND AROUND THE NUT PLATES ON THE PAX DOOR ENTRYWAY AT THE AFT DIGITAL PLATE. MAINTENANCE BLENDED OUT THE LIGHT CORROSION IAW EMB 135/145 SRM 53-21-10. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.