What was found
CLE FLT 2915 THE CREW REPORTED A LANDING GEAR AIR/GROUND FAIL MESSAGE ON THE EICAS TEMPORARILY AFTER GEAR RETRACTION. MAINTENANCE INSPECTED AND REPLACED THE NOSE LANDING GEAR DOOR SOLENOID VALVE. OPERATIONAL CHECKS WERE GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLE FLT 2915 THE CREW REPORTED A LANDING GEAR AIR/GROUND FAIL MESSAGE ON THE EICAS TEMPORARILY AFTER GEAR RETRACTION. MAINTENANCE INSPECTED AND REPLACED THE NOSE LANDING GEAR DOOR SOLENOID VALVE. OPERATIONAL CHECKS WERE GOOD.