What was found
SMOKE COMING FROM AREA OF THE PSU READING LIGHT ABOVE SEAT 1A. REMOVED AND REPLACED BALLAST RT8400 IAW EMB 145AMM 33-21-03 AND REPLACED NR 1 PSU CIRCUIT BOARD IAW EMB 145 VCMM 25-28-23. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SMOKE COMING FROM AREA OF THE PSU READING LIGHT ABOVE SEAT 1A. REMOVED AND REPLACED BALLAST RT8400 IAW EMB 145AMM 33-21-03 AND REPLACED NR 1 PSU CIRCUIT BOARD IAW EMB 145 VCMM 25-28-23. OPS CHECK GOOD.