What was found
CLE - FLT 3283 - CREW REPORTED A DUCT LEAK ON RIGHT SIDE, PERFORMED QRH ITEMS AND LIGHT EXTINGUISHED AT 3 MINUTES AFTER BLEED WAS CLOSED. AIRCRAFT RETURNED TO FIELD WITHOUT FURTHER INCIDENT. MAINTENANCE REMOVED AND REPLACED A DUCT LEAK SENSOR AND ALL OTHER SENSORS WERE CLEANED AS A PRECAUTION. OPERATIONAL AND LEAK CHECKS WERE SATISFACTORY IAW EMB-120 MM 36-10-00. (M)