What was found
IAH - DURING ROUTINE INSPECTION, FUSELAGE FRAME NR 41 LOWER FLOORBEAM WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE PERFORMED A REPAIR PER ATR-42 SRM AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IAH - DURING ROUTINE INSPECTION, FUSELAGE FRAME NR 41 LOWER FLOORBEAM WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE PERFORMED A REPAIR PER ATR-42 SRM AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)