What was found
CLE - FLT 3351 - CREW REPORTED THE EMERGENCY ESCAPE FLOOR LIGHTS DO NOT WORK FROM ROW 9 TO ROW 11. MAINTENANCE INSPECTED THE EMERGENCY LIGHTING SYSTEM THEN REMOVED AND REPLACED A FUSE AND ALSO REPAIRED A WIRE FOR PRECAUTIONARY REASON. THE EMERGENCY LIGHTING SYSTEM OPERATIONAL CHECKS WERE SATISFACTORY IAW EMB120 MM 33-50-00. AIRCRAFT RELEASED FOR SERVICE. (M)