As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
IAH - DURING C-CHECK INSPECTION, FOUND DEFECT INDICATIONS ON WINDSHIELD NODE NR 5 FASTENER LOCATIONS DURING ACCOMPLISHMENT OF SSI 53-11-27. MAINTENANCE REAMED THE DEFECTIVE HOLES UNTIL DEFECT WAS REMOVED AND INSTALLED OVERSIZE FASTENERS IAW CONTINENTAL EXPRESS ECRA 5310-01086. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)