What was found
IAH - DURING C-CHECK INSPECTION, THE PASSENGER DOOR ROTATING ARM TO FUSELAGE ATTACH FITTINGS WERE FOUND TO BE CORRODED AT FRAME 13A. MAINTENANCE REMOVED AND REPLACED THE AFFECTED ATTACH FITTING IAW EMB-120 SRM 51-40-02, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)