What was found
IAH - DURING C-CHECK INSPECTION, THE FLOOR SUPPORT BEAM AT FRAME 16 LEFT WAS FOUND TO BE CORRODED. MAINTENANCE PERFORMED DOUBLER REPAIR IAW EMB120 SRM 51-10-02, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IAH - DURING C-CHECK INSPECTION, THE FLOOR SUPPORT BEAM AT FRAME 16 LEFT WAS FOUND TO BE CORRODED. MAINTENANCE PERFORMED DOUBLER REPAIR IAW EMB120 SRM 51-10-02, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)