Service difficulty report · Valve · Beech 1900D

Difficulty date
January 21, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N81546
Make and model
Beech 1900D
Aircraft serial
UE187
Part
Valve
Part number
12938000113
Condition
Failed
Location
Rt Bleed Air
Part time
6,032 hours
Stage of operation
CR
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CLE - FLT 3161 - CREW REPORTED THAT THE RIGHT HAND BLEED AIR FAIL LIGHT ILLUMINATED IN-FLIGHT. AIRCRAFT RETURNED TO FIELD WITHOUT FURTHER INCIDENT. MAINTENANCE REMOVED AND REPLACED THE RIGHT HAND BLEED AIR SHUT OFF VALVE IAW B1900 MM 36-00-02, OPERATIONAL AND LEAK CHECKS WERE SATISFACTORY. AIRCRAFT RELEASED FOR SERVICE. (X)

More about the Beech 1900D