What was found
IAH - DURING C-CHECK INSPECTION, THE FLOOR BEAM AT FRAME 36 WAS FOUND CORRODED. MAINTENANCE PERFORMED A DOUBLER REPAIR ON THE AFFECTED FLOORBEAM IAW CONTINENTAL EXPRESS ENGINEERING CHANGE AND REPAIR AUTHORIZATION EC 5310-01037, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ACFT TT: 19,271.5 HOURS. CYCLES: 22,334. (X)