Service difficulty report · Circuit Breaker · Emb ERJ170200LR

Difficulty date
August 12, 2010
Submitted
August 13, 2010
Operation
Air carrier
Aircraft
N622CZ
Make and model
Emb ERJ170200LR
Aircraft serial
17000219
Aircraft time
6,283 hours, 3,667 cycles
Part
Circuit Breaker
Condition
Tripped
Location
Nr 1 Mau
Stage of operation
CR
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AVNX MAU 1 A FAIL CAUTION MESSAGE IN FLIGHT. FOUND MAU 1 POWER 1 CB ON LHCBP OUT. RESET CIRCUIT BREAKER AND PERFORMED FIM TASK 31-42-00-810-808-A. CHECKS OK.RESET MAU 1 NIC 1 AMM 45-45-00. PERFORMED RETURN TO SERIVE IAW AMM 27-00-00-070-801-A.