What was found
FLOOR SPLICE, HAS ONE SMALL SPOT OF CORROSION AROUND NUTPLATE RIVET AT FR 18. 13" OTBD OF RT FLOORBEAM. REMOVED CORROSION BY BLENDING AND TREATING IAW EMB SRM 51-10-03 & 51-12-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SPLICE, HAS ONE SMALL SPOT OF CORROSION AROUND NUTPLATE RIVET AT FR 18. 13" OTBD OF RT FLOORBEAM. REMOVED CORROSION BY BLENDING AND TREATING IAW EMB SRM 51-10-03 & 51-12-01.