What was found
LT WING INBD FLAP 2A, INBD TRACK, PN 170-39320-005, WORN OUT OF LIMITS THICKNESS REDUCTION D= .015", REF SRM 57-52-03, TABLE 101. BLENDED WORN AREA IAW SRM PART II 51-10-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT WING INBD FLAP 2A, INBD TRACK, PN 170-39320-005, WORN OUT OF LIMITS THICKNESS REDUCTION D= .015", REF SRM 57-52-03, TABLE 101. BLENDED WORN AREA IAW SRM PART II 51-10-03.