As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STARTED TO CLOSE FWD PAX DOOR . DOOR OPENED BY ITSELF HEARD LOUD HISSING NOISE. REPLACED FWD PAX DOOR PNEUMATIC ASSY DIAPHRAGM AND CHARGED BOTTLE TO 2300 PSI IAW AMM 52-11-53. PERFORMED LEAK CHECK AFTER 2 HOURS. CHECK NORMAL IAW AMM 52-11-51-614-801-A. OPEN RT-806625 TO RE-CHECK PRESSURE 1 DAY AND 2 DAY INTERVAL.