As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ATTACH FASTENER HOLES IS WORN OVERSIZE ON LT PYLON PANEL 419NR. REAMED FASTENER HOLE BACK TO ROUND & INSTALL NAS 1169C REPAIR WASHER IAW SRM 51-40-02 ON WORK ORDER 736922-440 IAW ETD 2014-170-019606 & EA E175-54-164.1 REV IR WORK ORDER 1412993.