As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT FLAP NR 3 INBD FLAP TRACK, PN 170-39315-002 HAS WIDTH REDUCTION OF .002 INCHES OUT OF LIMITS IAW SRM 57-55-03. BLENDED WORN AREAS IAW SRM PART II 51-10-03 ON WORK ORDER 740147-633 IAW ETD 2011-170 01072E & EA E175-57-188 2 REV IR WORK ORDER 1419937.