What was found
FORWARD CABIN RT FLOOR SILL IS EXFOLIATED BETWEEN FRAME 12 TO 1, RBL 37 TO 49+939.8 TO +1244.6. R & R FLOOR SILL 170-05663-003 IAW SRM 51-41-02 ON WO 6211852D8 IAW EO E175-5300-103 WO 1839418.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CABIN RT FLOOR SILL IS EXFOLIATED BETWEEN FRAME 12 TO 1, RBL 37 TO 49+939.8 TO +1244.6. R & R FLOOR SILL 170-05663-003 IAW SRM 51-41-02 ON WO 6211852D8 IAW EO E175-5300-103 WO 1839418.