What was found
WASTE PANEL CUT OUT RETAINERS, PN 170-86654-003 & 170-86655-003, HAVE CORROSION BETWEEN STATION 22270.0 TO 2268.0 & STRINGER 26R, Y= STRINGER 24R - 26R. PERMANENTLY REMOVED THE WASTE PAN RETAINERS ON WO 14988391H6 IAW EO E17X-5300-004 REV IR ON WO 694216.