THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF CORROSION DAMAGE TO THE AFT CABIN FLOOR STRUCTURE RT AFT SEAT TRACK PN 170-86082-003 AT FRAME 84. THE APPROX DAMAGE DIMENSIONS ARE AS FOLLOWS, 1.40 INCHES X 1.10 INCHES TO A MAXIMUM DEPTH OF .030 INCH DEEP. 1.0 INCHES X .175 INCH DEEP. BECAUSE THE FLOOR TRACK IS A PSE, ACCOMPLISHMENT OF THIS EO HAS BEEN CLASSIFIED AS A MAJOR REPAIR DUE TO STRENGTH RESTORATION. THIS IS NOT CLASSIFIED AS FCS, BUT REQUIRES FOLLOW UP INSPECTIONS THAT WILL BE ACCOMPLISHED ON EO E175-53MR-215.1 IAW ANAC DER FORM ATTACHED. TASK 53-23-005-0001, INTERNAL GVI THRESHOLD OF 20,483 FC OR 27,242 FH, INTERVAL OF 10,133 FC OR 13,476 FH IS SUFFICIENT & IS MET USING THE INSPECTION REQUIREMENTS, MPG & MRBR REVISION 11. THRESHOLD IS COUNTED SINCE NEW. ACCOMPLISHMENT OF THIS MAJOR REPAIR WAS ON EO E175-53MR-215 UNDER WO 1965079.