Service difficulty report · Floorbeam · Emb ERJ170200LR

Difficulty date
November 10, 2015
Submitted
November 10, 2015
Operation
Air carrier
Aircraft
N616CZ
Make and model
Emb ERJ170200LR
Aircraft serial
17000209
Aircraft time
21,657 hours, 12,496 cycles
Part
Floorbeam
Part number
17021769405
Condition
Corroded
Location
Zone 100
Part time
21,657 hours, 12,496 cycles
Stage of operation
IN
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF CORROSION DAMAGE TO THE CROSSBEAM FRAME 17, PN 170-21769-405 UPPER FLANGE, REF ETD 2015-170-102533 & FIGURE 1 FOR DAMAGE DIMENSIONS & LOCATIONS. 1.50 INCHES X .85 INCH TO A MAXIMUM DEPTH OF 0.046 INCHES DEEP & 1.250 INCHES X 0.85 INCH TO A MAXIMUM DEPTH OF 0.062 INCHES DEEP. REQUESTED & RECEIVED A REPAIR IN THE FORM OF ETD 2015-170-102533 FOR THE ACCOMPLISHMENT OF THE CROSSBEAM REPAIR ANGLE INSTALLATION. BECAUSE THE FLOOR CROSSBEAM IS PSE & FCS, ACCOMPLISHMENT OF THIS EO HAS BEEN CLASSIFIED AS A MAJOR REPAIR. FOLLOW UP INSPECTIONS WILL BE ACCOMPLISHED ON EO E175-53MR-217.1 IAW ANAC DER FORM ATTACHED. ACCOMPLISHMENT OF THIS PERMANENT REPAIR IS ON EO E175-53MR-217 UNDER WO 1982805. REF TASK 53-10-027-0001 INTERNAL GVI THRESHOLD OF 25,202FC, INTERVAL OF 25,202FC IS SUFFICIENT & IS MET USING THE INSPECTION REQUIREMENTS MPG & MRBR REVISION 11. THRESHOLD IS COUNTED SINCE NEW.