What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF CORROSION DAMAGE TO THE FR88 LOWER CENTER SECTION, P/N 170-65735-003. THE PERMANENT REPAIR WILL BE ACCOMPLISHED BY DIRECT REPLACEMENT IN ACCORDANCE WITH DRAWINGS AND SRM CHAPTER 51 PRINCIPLES. ACCOMPLISHMENT OF THIS EO HAS BEEN CLASSIFIED AS A MAJOR REPAIR BECAUSE FR88 IS A PSE AND FCS. SUPPLEMENTAL FOLLOW UP INSPECTIONS ARE NOT REQUIRED. THIS PERMANENT REPAIR WILL BE ACCOMPLISHED ON WO 2162496.