What was found
FWD CABIN FLOORBEAM FRAME 16 CORRODED AT Y -1050. X 4711. REMOVED AND REPLACED FLOORBEAM ANGLE IAW SRM 51-41-01 & 51-43-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN FLOORBEAM FRAME 16 CORRODED AT Y -1050. X 4711. REMOVED AND REPLACED FLOORBEAM ANGLE IAW SRM 51-41-01 & 51-43-01.