What was found
DURING CRUISE, THE CREW RECEIVED A HYD 1 LOW QTY EICAS MESSAGE. THE QRH WAS RUN AND THE STATUS WAS CONFIRMED. THE SYSTEM RESERVOIR DROPPED AS TIME WENT, ONCE THE SYSTEM RESERVOIR REACHED ZERO THE CREW DECLARED AN EMERGENCY WITH ATC DURING DESCENT. HYDRAULIC PRESSURE WAS MAINTAINED UNTIL SHORT FINAL WHERE HYD 1 EDP SHUT DOWN AND, JUST BEFORE THE FLARE, HYD SYS 1 LOST PRESSURE. THE FLIGHT LANDED SUCCESSFULLY AND TAXIED OFF THE RUNWAY WITH NO ISSUE. THE NR 1 MLG BRAKE HYD FUSE HOUSING WAS DISCOVERED LEAKING AT BRAKE OUTLET SIDE. R & R THE NR 1 BRAKE FUSE IAW AMM 32-41-15. OPS CHECKED GOOD. ACFT OK FOR SERVICE.