What was found
DURING CHECK, 5EA DENTS WERE DISCOVERED BETWEEN FR10/FR12 AND S-18L/S-19L DURING INSPECTION ON THE FORWARD FUSELAGE AFT LT LATERAL SKIN PANEL (P/N 170-03387-003). THE DENTS ARE OUT OF LIMITS OF SRM PART II 53-10-01/AD02 BECAUSE DENTS ARE NOT ALLOWED TO BE LOCATED IN ADJACENT BAYS. DENT A, LOCATED BETWEEN FR09/FR10 AND S-18L/S-19L, WAS FOUND WITH A CREASE JUST BELOW S-18L. IT REQUIRES A MORE EXTENSIVE REPAIR, WHICH CANNOT BE ACCOMPLISHED PER THE SRM BECAUSE IT IS IN AN NON-ALLOWED AREA OF SRM PART II 53-10-01/REPAIR 12P. RECEIVED ETD2018-170-094815A, WHICH ALLOWS THE DENTS B-E TO BE CONSIDERED PERMANENT ALLOWABLE DAMAGE AND PROVIDES INSTRUCTIONS TO ACCOMPLISH A CUT OUT AND DOUBLER REPAIR OF THE CREASED REGION OF DENT A. EA E175-53-1013 REV IR WAS ISSUED TO ACCOMPLISH THE MINOR REPAIR OF DENTS B-E. THIS EO HAS BEEN CLASSIFIED AS A MAJOR REPAIR.