Service difficulty report · Doubler · Emb ERJ170200LR

Difficulty date
April 4, 2019
Submitted
April 4, 2019
Operation
Air carrier
Aircraft
N606CZ
Make and model
Emb ERJ170200LR
Aircraft serial
17000188
Aircraft time
30,858 hours, 18,554 cycles
Part
Doubler
Part number
17003237005
Condition
Corroded
Location
Zone 100
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING THE B6 BASIC CHECK AT EAMS, CORROSION DAMAGE WAS DISCOVERED IN THE FORWARD FUSELAGE AT THE LH COCKPIT FLOOR DOUBLER (P/N 170-03237-005) DURING INSPECTION IN THE AREA. THE DAMAGE EXCEEDED THE LIMITS PROVIDED IN THE SRM BECAUSE OF ITS DEPTH. EAMS REQUESTED AND RECEIVED APPROVED REPAIR DISPOSITION FROM RTS IN THE FORM OF ETD2019-170-044373 AND ITS CORRESPONDING ANAC DER FORM. THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH A PERMANENT REPAIR OF CORROSION TO THE LH COCKPIT FLOOR DOUBLER BY SPLICING IN A NEW SECTION OF THE FLOOR DOUBLER PER ETD2019-170-044373. ACCOMPLISHMENT OF THIS EO HAS BEEN CLASSIFIED AS A MAJOR REPAIR BECAUSE THE LH COCKPIT FLOOR DOUBLER IS A PSE AND THIS EO IS RESTORING STRENGTH. SUPPLEMENTAL FOLLOW-ON INSPECTIONS ARE NOT REQUIRED PER ETD2019-170-044373. EO E175-53MR-413 IS BEING ACCOMPLISHED BY WO 2636244