What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH A PERMANENT REPAIR OF ELECTRICAL ARC DAMAGE TO FRAME 10, P/N 170-03310-403, BETWEEN S-12L/S13L. THE DAMAGE IS A HOLE THAT MEASURES APPROXIMATELY 0.592 INCH IN LENGTH AND 0.544 INCH IN WIDTH (REF ETD2019-170-049559, FIGURE 1). EAMS REQUESTED AND RECEIVED A PERMANENT REPAIR IN THE FORM OF ETD2019-170-049559 WHICH ALLOWS THE DAMAGE TO BE REPAIRED BY A DOUBLER INSTALLATION. BECAUSE FRAME 10 IS PSE AND THE REPAIR IS RESTORING STRENGTH, ACCOMPLISHMENT OF THIS EO HAS BEEN CLASSIFIED AS A MAJOR REPAIR. EO E175-53MR-411 IS BEING ACCOMPLISHED BY WO 2640573.