What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-86181-005 RH PANEL SUPPORT, P/N 170-60259-001 FR90 GUSSET, P/N 170-60257-001 FR90 GUSSET, P/N 170-86125-001 FR89 RH SPLICE, P/N 170-65927-007 LH SHEAR PANEL, P/N 170-65928-001 CENTER SHEAR PANEL, P/N 170-91919-001 RH SHEAR PANEL, P/N 170-92908-001 RH PANEL SUPPORT. REPLACEMENT OF PARTS IS ACCOMPLISHED IN ACCORDANCE WITH EMBRAER DRAWINGS LISTED IN TABLE 2 AND SRM CHAPTER 51 PRINCIPLES. SUPPLEMENTAL FOLLOW UP INSPECTIONS WILL NOT BE REQUIRED FOR DIRECT REPLACEMENT OF THE FLOOR STRUCTURE. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR.