What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: P/N 170-05663-003 (170-05663-005) RH FLOOR SILL, P/N 170-04071-001 FR15 RH FLOOR SUPPORT, P/N 170-04071-001 FR16 RH FLOOR SUPPORT AND P/N 170-13939-001, FR17 FLOOR SUPPORT . REPLACEMENT OF PARTS IS ACCOMPLISHED IN ACCORDANCE WITH EMBRAER DRAWINGS LISTED IN TABLE 2 AND SRM CHAPTER 51 PRINCIPLES. SUPPLEMENTAL FOLLOW UP INSPECTIONS WILL NOT BE REQUIRED FOR DIRECT REPLACEMENT OF THE FLOOR STRUCTURE. COMPASS ENGINEERING HAS CLASSIFIED THIS A MINOR REPAIR.