What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86181-005 RH PANEL SUPPORT, P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-86119-005 FR90 CENTER SPLICE, P/N 170-60257-001 FR90 LH IB GUSSET, P/N 170-92908 RH PANEL SUPPORT, P/N 170-91919-001 RH SHEAR PANEL. REPLACEMENT OF PARTS IS ACCOMPLISHED IN ACCORDANCE WITH EMBRAER DRAWINGS LISTED IN TABLE 2 AND SRM CHAPTER 51 PRINCIPLES. SUPPLEMENTAL FOLLOW UP INSPECTIONS WILL NOT BE REQUIRED FOR DIRECT REPLACEMENT OF THE FLOOR STRUCTURE. COMPASS ENGINEERING HAS CLASSIFIED THIS A MINOR REPAIR. WORK ORDER 2763525