What was found
DURING BASIC CHECK AT EAMS, CORROSION DAMAGE WAS FOUND TO THE CENTER FUSELAGE III LH AFT PANEL SUPPORT P/N 170-86139-005. REFERENCE ETD2019-170-153585 FIGURE 1 FOR DETAILS, FOR THE DAMAGE LOCATIONS AND DIMENSION. EAMS REQUESTED AND RECEIVED PERMANENT REPAIR DISPOSITION IN THE FORM OF ETD2019-170-153585, WHICH ALLOW THE AREAS TO BE BLENDED AND LEAVE AS-IS, PROVIDED NDT INSPECTION VERIFIES DAMAGE REMOVAL AND SURFACE PROTECTION IS RESTORED. W.O.#2739004445