What was found
DURING BASIC CHECK AT EAMS, INSPECTION DISCOVERED MINOR NICK/TOOLING DAMAGE ON THE RH WING #1 SPOILER ACTUATOR FITTING ASSEMBLY, P/N 170-34105-406. THERE ARE 14 AREAS OF DAMAGE ON THE ASSEMBLY. REF ETD2019-170-144300, FIGURE 1-4 FOR DAMAGE INFORMATION. THE DAMAGES ARE OUT OF LIMITS OF SRM PART II 57-71-00/AD01 BECAUSE THE BLEND-OUTS ARE LOCATED IN A NO DAMAGE ALLOWED AREA. EAMS REQUESTED AND RECEIVED A PERMANENT REPAIR IN THE FORM OF ETD2019-170-144300 WHICH PROVIDES A REPAIR BY BLEND-OUT. COMPASS ENGINEERING HAS CLASSIFIED THIS REPAIR AS A MINOR REPAIR. WORK ORDER 2759395