What was found
DURING BASIC CHECK AT EAMS, INSPECTION DISCOVERED A DENT ON THE FORWARD FUSELAGE SKIN BETWEEN FR13 & FR14 AND STGR-19L & THE SKIN SEAM. REFER ETD2019-170-156012 FOR THE DENT LOCATION AND MEASUREMENTS. EAMS REQUESTED AND RECEIVED RELIEF IN THE FORM OF ETD2019-170-156012 WHICH PROVIDES INSTRUCTIONS TO ACCOMPLISH INSPECTIONS OF THE DENT AREA TO VERIFY NO SHARP EDGES, CREASES, OIL CANNING, OR DISCREPANT FASTENERS ARE PRESENT. NDT HFEC INSPECTION IS ALSO REQUIRED TO VERIFY NO CRACKS EXIST. IF THE DENTED AREA IS FOUND DAMAGE FREE, THE DENT IS CONSIDERED PERMANENT ALLOWABLE DAMAGE. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR. WORK ORDER 2792520