What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE IN THE FORWARD AND AFT CABIN FLOOR STRUCTURE BY REPLACEMENT OF THE FOLLOWING: P/N 170-05663-005 RH FLOOR SILL, P/N 170-65928-001 CENTER SHEAR PANEL, P/N 170-91919-001 RH SHEAR PANEL, P/N 170-86181-005 RH PANEL SUPPORT, P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-86125-001 FR89 SPLICE. REPLACEMENT OF PARTS IS ACCOMPLISHED IN ACCORDANCE WITH EMBRAER DRAWINGS LISTED IN TABLE 2 AND SRM CHAPTER 51 PRINCIPLES. SUPPLEMENTAL FOLLOW UP INSPECTIONS WILL NOT BE REQUIRED FOR DIRECT REPLACEMENT OF THE FLOOR STRUCTURE. COMPASS ENGINEERING HAS CLASSIFIED THIS A MINOR REPAIR.FRAME 89. X=963.0", Y=+10.75", Z=-19.3".W.O.# 2815473243