What was found
DURING BASIC CHECK AT EAMS, SCRATCH DAMAGE WERE DISCOVERED ON THE CENTER FUSELAGE I LOWER RIGHT SKIN PANEL (P/N 170-92574-005) AT FR 27 BELOW STGR 20R. THE SCRATCH IS REPORTED TO HAVE THE FOLLOWING DIMENSIONS: 3.95 INCHES X 0.58 INCH TO A MAX DEPTH OF 0.009 INCHES. (REF ETD2019-170-158822C) THIS DAMAGE IS OUT OF LIMITS PER SRM PART II 53-21-01/AD01 BECAUSE IT IS LOCATED IN AN AREA WHERE “NO DAMAGE IS ALLOWED.” EAMS REQUESTED AND RECEIVED DISPOSITION FOR A PERMANENT REPAIR IN THE FORM OF ETD2019-170-158822C WHICH ALLOWS THE DAMAGE TO BE BLENDED PROVIDED NDT INSPECTION VERIFIES COMPLETE DAMAGE REMOVAL AND SURFACE PROTECTION IS RESTORED. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR. WORK ORDER 2798793