What was found
DURING BASIC CHECK AT EAMS, CORROSION WAS DISCOVERED ON FORWARD FUSELAGE FLOOR SUPPORT (P/N 170-29704-001) AT FR19. REFERENCE ETD2019-170-079113, FIGURE 1 FOR THE DAMAGE LOCATION AND DIMENSIONS. THERE ARE NO PUBLISHED LIMITS FOR THIS FITTING. EAMS REQUESTED AND RECEIVED DISPOSITION FOR A PERMANENT REPAIR IN THE FORM OF ETD2019-170-079113, WHICH ALLOWS THE CORROSION TO BE BLENDED PROVIDED NDT INSPECTION VERIFIES COMPLETE DAMAGE REMOVAL AND SURFACE PROTECTION IS RESTORED. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR. X=5,695MM Y=-1,150MM Z=-490 W.O.# 2523875401