What was found
DURING BASIC CHECK AT EAMS, INSPECTION DISCOVERED CORROSION DAMAGE ON THE AFT PASSENGER DOOR LOWER BEAM P/N 170-65703-005. REFERENCE ETD2019-170-078965, FIGURES 1 AND 2 FOR DAMAGE DETAILS. EAMS REQUESTED AND RECEIVED A PERMANENT REPAIR OF THE EDGE DAMAGE IN THE FORM OF ETD2019-170-078965 WHICH ALLOWS THE CORROSION TO BE BLENDED OUT AND THEN NDT INSPECTED FOR VERIFICATION OF DAMAGE REMOVED. EA E175-53-1085 IS BEING ISSUED TO ACCOMPLISH THE PERMANENT REPAIR OF AFT PASSENGER DOOR LOWER BEAM CORROSION DAMAGE. COMPASS ENGINEERING HAS CLASSIFIED THIS REPAIR AS A MINOR REPAIR. X=23,130MM TO 23,710MM;Y=1,168MM TO 1,142MM;Z=-490 TO -490.W.O.#2523875380