What was found
DURING BASIC CHECK AT EAMS, CORROSION DAMAGE WAS FOUND TO THE CENTER FUSELAGE III RH PANEL SUPPORT P/N 170-86181-005. REFERENCE ETD2019-170-160096 FIGURE 1 FOR DETAILS, FOR THE DAMAGE LOCATIONS AND DIMENSION. EAMS REQUESTED AND RECEIVED PERMANENT REPAIR DISPOSITION IN THE FORM OF ETD2019-170-160096, WHICH ALLOW THE AREAS TO BE BLENDED AND LEAVE AS-IS, PROVIDED NDT INSPECTION VERIFIES DAMAGE REMOVAL AND SURFACE PROTECTION IS RESTORED. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR. W.O.#2802551