What was found
DURING BASIC CHECK AT EAMS, CORROSION WAS FOUND ON THE FOLLOWING FORWARD FUSELAGE LH FLOOR SILL P/N 170-05662-001 AT FRAME 19. REFERENCE ETD2019-170-160022, FIGURE 1, FOR THE DAMAGE LOCATIONS AND DIMENSIONS. EAMS REQUESTED AND RECEIVED PERMANENT REPAIR DISPOSITION IN THE FORM OF ETD2019-170-160022, WHICH ALLOW THE AREAS TO BE BLENDED PROVIDED NDT INSPECTION VERIFIES DAMAGE REMOVAL AND SURFACE PROTECTION IS RESTORED. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR. W.O.#2802523