What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: P/N 170-12118-001 FLOOR DOUBLER, P/N 170-03275-005 LH FLOOR SILL, P/N 170-04071-001 FR16 RH FLOOR SUPPORT, P/N 170-04075-001 FR14 FLOOR PANEL ANGLE. REPLACEMENT OF PARTS IS ACCOMPLISHED IN ACCORDANCE WITH EMBRAER DRAWINGS LISTED IN TABLE 2 AND SRM CHAPTER 51 PRINCIPLES. SUPPLEMENTAL FOLLOW UP INSPECTIONS WILL NOT BE REQUIRED FOR DIRECT REPLACEMENT OF THE FLOOR STRUCTURE. COMPASS ENGINEERING HAS CLASSIFIED THIS A MINOR REPAIR. FWD LH SILL, FRAME 16, X= 4711.0 MM, Y= -1173.0MM, Z= -490.0 MM.W.O.#2523875389