What was found
WHILE IN INSPECTION, IT WAS NOTED THAT THE FLOORBEAM AT BS 1130 RBL 50 IS CORRODED. REMOVED CORROSION, CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED FILLER FROM 7075 T6 DIM 1.5 INCH X 1.25 INCH .160 INCH, STRAP 7075 T6 1 INCH X 10 INCH .160 INCH, STRAP 7075 T6 DIM 4 INCH X 9.5 INCH .063 INCH, ANGLE 7075-0 DIM 3.5 X 7.5 INCH .050 INCH. INSTALLED REPAIR, NO OTHER DEFECTS WERE NOTED. ACFT WAS RETURNED TO SERVICE.