As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE IN HEAVY MX PERFORMING INSP, CORROSION WAS NOTED ON THE STRINGER 29L STATION 950B. REMOVED CORROSION FROM STRINGER, FABRICATED REPAIR STRAP FROM 7075 T6 .063" 8.5" INSTALLED REPAIR, NO OTHER DEFECTS NOTED. ACFT WAS RETURNED TO SERVICE.