What was found
(CAN) CENTER HYD PUMP FAILED IN CRUISE ELECTRICAL BURN SMELL IN COCKPIT, SMOKE EVIDENT, PUMP SHUT OFF, SMOKE DISSIPATED. SWAPPED C1 AND C2 DELAY MODULE AND CHANGED C1 LIGHT SWITCH. ON CLIMB THERE WAS A BURNING SMELL, C1 HYD SYSTEM SHUT DOWN A/C DIVERTED. FOUND C1 SWITCH LIGHT AND C2 DELAY MODULES BURNT. NEW TIME DELAY INSTALLED AND C2 POSITION SWAPPED FOR RECIRC FAN SWITCH.