What was found
(CAN) LEFT ENGINE MAJOR POWER FLUCTUATION, COMPUTER OFF NO CHANGE. OIL PRESSURE LIGHT ON 10-15 SEC. OIL PRESSURE RECOVERED. HYD. PUMP DROP TO 2000 PSI TANK LIGHT ON. 1) ENGINE GROUND UN ADJ. (IDLE, ADJ.) 1/2 TURN FLUCTUATION STOPPED ON HIGH POWER.. OIL PRESSURE CHECKED FOUND 42 LB 48 TAKE OFF POWER OIL FILTER CHECKED / FUEL FILTER CHECKED OK. BIZJET SENT ANOTHER FCU CHANGED UNIT GROUND RUN CHECKED OK. SUSPECTED FCU FAILURE DUE TO NO POWER CONTROL ON MANUAL MODE.