What was found
(CAN) A/C 641, AUG 20/2000, FLT 30, LOG SEQUENCE 0225444. AT APPROXIMATELY 14,000 FEET, LEADING EDGE SLAT ASYMMETRY WARNING ILLUMINATED ON EICAS, FLAP POSITION NEEDLE INDICATED BETWEEN 1 UNIT AND UP. RETURNED TO PEK. BITE CHECK COMPLETED ON PSEU, NIL FAULTS INDICATED. SLATS AND FLAPS EXTENSION CHECKED SEVERAL TIMES NO FAULTS FOUND. COCKPIT INDICATION CHECKED OK.