Service difficulty report · Heater · Pilats PC1245

Difficulty date
October 18, 2000
Submitted
November 2, 2000
Operation
Air carrier
Make and model
Pilats PC1245
Part
Heater
Part number
9696781505
Condition
Failed
Location
Cockpit Floor
Part time
194 hours, 137 cycles
Component
Heating System
Stage of operation
IN
How discovered
C
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING A 100-HOUR INSPECTION, A TEST OF THE THERMAL PROTECTION SWITCH IS REQUIRED. AN AIR BLOCKAGE TEST IS REQUIRED TO DETERMINE IF THE THERMAL SWITCH WILL STOP ELECTRICAL POWER SUPPLY TO THE FOOT HEATER. THREE MINUTES INTO THE TEST, THE UNIT BEGAN TO SMOKE. THE TEST REQUIRES THAT THE THERMAL SWITCH CUT POWER TO THE HEATER WITHIN THREE TO FIVE MINUTES FROM THE START OF THE TEST. AFTER FIVE MINUTES, THE UNIT WAS HOT TO THE TOUCH, AND SMOKE CONTINUED TO COME FROMTHE UNIT. THE TEST WAS TERMINATED. A NEW FOOT WARMER WAS ORDERED AND THE SYSTEM WAS PLACARDED; NOT FOR USE, AND THE CIRCUIT BREAKER WAS PULLED. (X)