Service difficulty report · Smoke Detector · Cndair CL6002B19

Difficulty date
November 1, 2000
Submitted
January 19, 2001
Operation
General aviation
Make and model
Cndair CL6002B19
Part
Smoke Detector
Part number
473052
Condition
Failed
Location
Cargo Bay
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CARGO SMOKE WARNING CAME ON DURING CRUISE FLIGHT. CREW FOLLOWED QRH. BOTH EXTINGUISHER BOTTLES BLOWN. MESSAGE REMAINED. DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT, RETURNING TO CVG. R&R THE CARGO SMOKE DETECTOR BOXES.