What was found
(CAN) A CHIP DETECTOR LIGHT ILLUMINATED & INSP OF DETECTOR SHOWED SLIVER OF METAL. SUBSEQUENT OIL FILTER CHANGES / INSPECTIONS, GROUND RUNS & FILTER INSPECTION AGAIN INDICATED METAL CONTAMINATION IN OIL.. ENGINE REMOVED FOR OVERHAUL & RETURNED TO THE MFG. ENGINE OPERATED ONLY 12.1 HRS SINCE OVERHAUL BY ALLIED SIGNAL - HONEYWELL.2000-12-07TC: FOLLOW-UP REPORT EXPECTED FROM OPERATOR AFTER TEARDOWN. 2000-12-14TC: FOLLOW UP REPORT IS RESULT OF ENGINE CONDITION REPORT RECEIVED FROM ENGINE MFG FOLLOWING TEARDOWN INVEST. THE PLANETARY REDUCTION GEAR ASSY EXHIBITED PITTING ON TEETH. ID OF GEAR (OUTER RACE OF ROLLER BEARING) SHOWED HEAVY SCORING, WITH EVIDENCE OF HEAVY SKIDDING & HEAT GENERATION