Service difficulty report · Smoke Detector · Airbus A310304

Difficulty date
November 26, 2000
Submitted
January 19, 2001
Operation
Air carrier
Make and model
Airbus A310304
Part
Smoke Detector
Part number
CG7GO10
Condition
Malfunctioned
Location
Min Bay
Part time
9,354 hours, 3,021 cycles
Component
Smoke Detector
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) JUST AFTER TAKEOFF, MIN BAY SMOKE INDICATION APPEARED, THEN DISAPPEARED AFTER 10 SECONDS. FLIGHT CREW CHECKED MIN BAY SNIFFER TUBE SYSTEM, NO SMOKE WAS DETECTED. CREW ELECTED TO RETURN TO BASE. ON GROUND NO EVIDENCE OF SMOKE OR BURNING COULD BE FOUND AND SYSTEM TESTED SERVICEABLE. SMOKE DETECTOR 12WA REPLACED AS PER AMM 26-15-12. OFF PART NUMBER 2-2610-9-0003 SERIAL NUMBER 0605, ON SERIAL NUMBER 0673. AVIIONICS, CARGO SMOKE DETECTION TEST COMPLETED. SYSTEM CHECK SERVICEABLE.